Description
FiberLock IAQ 6000 features a 100% acrylic water-based coating and anti-fungal agents which prevents mould from growing on dry surfaces. This product is used by professional for dry coating on surfaces such as wood, plaster, wallboard, sheetrock, concrete, masonry block, primed metal, and galvanized metal.
FEATURES
- Tested by independent laboratories for mould resistance: ASTMG-21 and ASTM D-3273
- Mould resistant*
- 100% acrylic
*Resistant to mould growth on the dry coating surface only
How to Use
SURFACE PREPARATION
Surfaces to be coated must be free of dust, mildew, mould, dirt, grease, loose paint, oil, glue size, calcimine, wax, soap and other surface contamination. Clean mould stained surfaces with Advanced Peroxide Cleaner, or use an EPA registered antimicrobial disinfectant cleaner such as IAQ 2000, IAQ 2500, ShockWave or ShockWave RTU. Patch irregularities with vinyl patching paste or an appropriate patching compound. IAQ 6100 is self-priming over bare sheetrock, composition board, ceiling tile and concrete.
WALLBOARD, SHEETROCK, GYPSUM BOARD
Joint cement should be sanded smooth, but avoid abrading the paper.
APPLICATION TOOLS
Apply IAQ 6000 with brush, roller or airless spray equipment.
PRODUCT APPLICATION
IAQ 6000 is supplied ready to use, but can be thinned sparingly with water (up to 200mL per 4L) for proper application consistency if necessary. Apply IAQ 6000 generously and uniformly by brush, roller, or airless spray. Apply one coat of IAQ 6000 and ensure that the finished surface is properly sealed. To ensure that the finished surface is properly sealed, two-coats may be required on some porous surfaces.
COVERAGE
- Smooth Surfaces- 32-55m². 4 liters
- Porous Surfaces- 23-27m². 4 liters
DRYING TIME
- @ 22°C 50% R.H
- To Touch – 1 Hour
- Recoat – 4-8 Hours
CLEANUP
Clean tools and drippings with warm soapy water before Fiberlock IAQ 6000 dries. Dispose of all waste according to all existing local, state and federal regulations.
PRECAUTIONS
Store in a dry place at temperatures between 4.5°C and 32°C. Stir thoroughly. Do not mix with any other coatings, solvents or colors in oil. The IAQ 6000 coating is resistant to mould only on the surface of the coating. No mould resistance claim is made other than to the coating itself. The use of this product does not protect users or others against food-borne or disease-causing bacteria, viruses, germs or other disease-causing organisms. Do not apply when air or surface temperature is below 10°C, or when drying conditions are poor or when surfaces are above a 15% moisture level content. Use adequate ventilation during application. When applying with a sprayer, wear a NIOSH approved respirator with any R, P, N or HE filter. For interior use only.